{"id":5974,"date":"2026-09-18T15:37:35","date_gmt":"2026-09-18T07:37:35","guid":{"rendered":"https:\/\/www.sj-gauge.com\/?p=5974"},"modified":"2026-09-18T15:56:27","modified_gmt":"2026-09-18T07:56:27","slug":"industrial-thermometer-slow-response","status":"publish","type":"post","link":"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/","title":{"rendered":"\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u53cd\u5fdc\u304c\u9045\u3044\u306e\u306f\u306a\u305c\uff1f5\u3064\u306e\u539f\u56e0\u3068\u89e3\u6c7a\u7b56"},"content":{"rendered":"<p>\u6a5f\u5668\u304c\u52a0\u71b1\u3055\u308c\u308b\u3068\u3001\u6e29\u5ea6\u8a08\u306e\u91dd\u304c\u8ffd\u5f93\u3059\u308b\u306e\u306b\u6642\u9593\u304c\u304b\u304b\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u51b7\u5374\u4e2d\u3082\u3001\u3057\u3070\u3089\u304f\u306e\u9593\u3001\u8868\u793a\u5024\u304c\u9ad8\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u5fc5\u305a\u3057\u3082\u6545\u969c\u3092\u793a\u3059\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u71b1\u304c\u5a92\u4f53\u304b\u3089\u611f\u77e5\u7d20\u5b50\u306b\u4f1d\u308f\u308b\u306b\u306f\u6642\u9593\u304c\u304b\u304b\u308a\u3001\u305d\u306e\u9045\u5ef6\u306f\u30b9\u30c6\u30e0\u3001\u8a2d\u7f6e\u4f4d\u7f6e\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306a\u3069\u306b\u3088\u3063\u3066\u5f71\u97ff\u3092\u53d7\u3051\u308b\u305f\u3081\u3067\u3059\u3002.<\/p>\n\n\n\n<p>\u307e\u305a\u3001\u30d7\u30ed\u30bb\u30b9\u6e29\u5ea6\u304c\u5b89\u5b9a\u3057\u305f\u5f8c\u3082\u6709\u610f\u306a\u5dee\u304c\u6b8b\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30d7\u30ed\u30bb\u30b9\u306b\u5bfe\u3057\u3066\u5fdc\u7b54\u304c\u9045\u3059\u304e\u308b\u5834\u5408\u3068\u3001\u6e2c\u5b9a\u8aa4\u5dee\u304c\u7d99\u7d9a\u7684\u306b\u767a\u751f\u3057\u3066\u3044\u308b\u5834\u5408\u3092\u533a\u5225\u3067\u304d\u307e\u3059\u3002\u8fc5\u901f\u306a\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001\u8a2d\u7f6e\u6e08\u307f\u306e\u30a2\u30bb\u30f3\u30d6\u30ea\u5168\u4f53\u306e\u5fdc\u7b54\u6642\u9593\u3001\u7bc4\u56f2\u3001\u304a\u3088\u3073\u7cbe\u5ea6\u3092\u6307\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\" style=\"width:640px;max-width:100%;margin:32px auto\"><img fetchpriority=\"high\" decoding=\"async\" width=\"2400\" height=\"1256\" src=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg\" alt=\"Rear view of an industrial thermometer showing its long sensing stem and threaded process connection\" class=\"wp-image-5980\" style=\"display:block;width:100%;height:auto;aspect-ratio:3\/2;object-fit:cover;object-position:center\" srcset=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg 2400w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-300x157.jpg 300w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-1024x536.jpg 1024w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-768x402.jpg 768w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-1536x804.jpg 1536w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-2048x1072.jpg 2048w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-18x9.jpg 18w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response-600x314.jpg 600w\" sizes=\"(max-width: 2400px) 100vw, 2400px\" \/><figcaption class=\"wp-element-caption\">\u56f31\uff5c\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u611f\u77e5\u30b9\u30c6\u30e0\u3068\u306d\u3058\u8fbc\u307f\u63a5\u7d9a\u90e8\u3002\u30b9\u30c6\u30e0\u306e\u5bf8\u6cd5\u3068\u8a2d\u7f6e\u6761\u4ef6\u306f\u3001\u6e29\u5ea6\u5909\u5316\u304c\u611f\u77e5\u7d20\u5b50\u306b\u4f1d\u308f\u308b\u901f\u5ea6\u306b\u5f71\u97ff\u3057\u307e\u3059\u3002.<\/figcaption><\/figure>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u76ee\u6b21<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u76ee\u6b21\u306e\u8868\u793a\/\u975e\u8868\u793a\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u30c8\u30b0\u30eb<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #7b1e1c;color:#7b1e1c\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #7b1e1c;color:#7b1e1c\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#cause-1-different-sensing-principles-and-designs\" >\u539f\u56e0\uff11\uff1a\u7570\u306a\u308b\u30bb\u30f3\u30b7\u30f3\u30b0\u539f\u7406\u3068\u8a2d\u8a08<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#cause-2-stem-size-and-thermal-mass\" >\u539f\u56e0\uff12\uff1a\u830e\u306e\u30b5\u30a4\u30ba\u3068\u71b1\u5bb9\u91cf<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#cause-3-insufficient-immersion-or-an-unsuitable-measuring-position\" >\u539f\u56e0\uff13\uff1aImmersion\u4e0d\u8db3\u307e\u305f\u306f\u4e0d\u9069\u5207\u306a\u6e2c\u5b9a\u4f4d\u7f6e<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#cause-4-low-flow-or-a-stagnant-measuring-point\" >\u539f\u56e04\uff1a\u6d41\u91cf\u4e0d\u8db3\u307e\u305f\u306f\u6e2c\u5b9a\u30dd\u30a4\u30f3\u30c8\u306e\u505c\u6ede<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#cause-5-heat-transfer-through-the-thermowell\" >\u539f\u56e0\uff15\uff1a\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u901a\u3058\u305f\u71b1\u4f1d\u9054<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#how-can-you-improve-an-industrial-thermometers-response\" >\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u5fdc\u7b54\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#international-standards-references\" >\u56fd\u969b\u898f\u683c\u306e\u53c2\u7167<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#frequently-asked-questions\" >\u3088\u304f\u3042\u308b\u8cea\u554f<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/#conclusion\" >\u307e\u3068\u3081<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\" id=\"sensing-principle\"><span class=\"ez-toc-section\" id=\"cause-1-different-sensing-principles-and-designs\"><\/span>\u539f\u56e0\uff11\uff1a\u7570\u306a\u308b\u30bb\u30f3\u30b7\u30f3\u30b0\u539f\u7406\u3068\u8a2d\u8a08<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u30d0\u30a4\u30e1\u30bf\u30eb\u5f0f\u6e29\u5ea6\u8a08\u3084\u81a8\u5f35\u5f0f\u6e29\u5ea6\u8a08\u3001\u305d\u3057\u3066\u71b1\u96fb\u5bfe\u3084\u6e2c\u6e29\u62b5\u6297\u4f53\u3092\u7528\u3044\u305f\u96fb\u5b50\u5f0f\u6e2c\u5b9a\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u305d\u308c\u305e\u308c\u5fdc\u7b54\u7279\u6027\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u540c\u3058\u5a92\u4f53\u3092\u540c\u3058\u5834\u6240\u3067\u6e2c\u5b9a\u3057\u305f\u5834\u5408\u3067\u3082\u3001\u52a0\u71b1\u6642\u3084\u51b7\u5374\u6642\u306b\u6e2c\u5b9a\u5024\u304c\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u300c\u6a5f\u68b0\u5f0f\u300d\u3068\u300c\u96fb\u5b50\u5f0f\u300d\u3068\u3044\u3046\u8868\u793a\u3060\u3051\u3067\u306f\u3001\u3069\u3061\u3089\u306e\u6a5f\u5668\u304c\u3088\u308a\u901f\u304f\u5fdc\u7b54\u3059\u308b\u304b\u306f\u5224\u65ad\u3067\u304d\u307e\u305b\u3093\u3002.<\/p>\n\n\n\n<p>\u4f8b\u3048\u3070\u3001 <a href=\"https:\/\/www.sj-gauge.com\/ja\/product\/mtr_s\/\" target=\"_blank\" rel=\"noopener\">MTR.S \u6bdb\u7d30\u7ba1\u81a8\u5f35\u6e29\u5ea6\u8a08<\/a> \u30c7\u30a3\u30b9\u30d7\u30ec\u30a4\u3068\u691c\u77e5\u70b9\u3092\u5206\u96e2\u3059\u308b\u3053\u3068\u3067\u3001\u9060\u9694\u8868\u793a\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u306e\u8a2d\u7f6e\u4e0a\u306e\u5229\u70b9\u306f\u5fc5\u305a\u3057\u3082\u5fdc\u7b54\u901f\u5ea6\u306e\u5411\u4e0a\u3092\u610f\u5473\u3059\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u691c\u77e5\u7528\u96fb\u7403\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3001\u304a\u3088\u3073\u5b9f\u969b\u306e\u52d5\u4f5c\u6761\u4ef6\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n\n\n\n<figure class=\"wp-block-image\" style=\"width:640px;max-width:100%;margin:32px auto\"><div style=\"width:100%;aspect-ratio:3\/2;overflow:hidden\"><img decoding=\"async\" width=\"2560\" height=\"1922\" src=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-scaled.jpg\" alt=\"SJ Gauge capillary thermometer showing the dial, capillary and sensing bulb\" class=\"wp-image-5975\" sizes=\"(max-width: 640px) 270vw, 1728px\" loading=\"eager\" style=\"display:block;width:100%;height:100%;object-fit:cover;transform:scale(2.7);transform-origin:49% 54%\" srcset=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-scaled.jpg 2560w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-300x225.jpg 300w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-1024x769.jpg 1024w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-768x577.jpg 768w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-1536x1153.jpg 1536w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-2048x1538.jpg 2048w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-16x12.jpg 16w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-capillary-thermometer-response-600x450.jpg 600w\" \/><\/div><figcaption class=\"wp-element-caption\">\u56f32\uff5c\u6bdb\u7d30\u7ba1\u6e29\u5ea6\u8a08\u3002\u9060\u9694\u8868\u793a\u306f\u8868\u793a\u88c5\u7f6e\u3068\u6e2c\u5b9a\u70b9\u3092\u5206\u96e2\u3059\u308b\u3082\u306e\u3067\u3042\u308a\u3001\u305d\u308c\u81ea\u4f53\u304c\u5fdc\u7b54\u901f\u5ea6\u306e\u5411\u4e0a\u306b\u3064\u306a\u304c\u308b\u308f\u3051\u3067\u306f\u306a\u3044\u3002.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"stem-size\"><span class=\"ez-toc-section\" id=\"cause-2-stem-size-and-thermal-mass\"><\/span>\u539f\u56e0\uff12\uff1a\u830e\u306e\u30b5\u30a4\u30ba\u3068\u71b1\u5bb9\u91cf<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u4ed6\u306e\u6761\u4ef6\u304c\u540c\u7b49\u306e\u5834\u5408\u3001\u4e00\u822c\u7684\u306b\u3001\u3088\u308a\u592a\u3044\u307e\u305f\u306f\u3088\u308a\u5927\u304d\u306a\u30bb\u30f3\u30b7\u30f3\u30b0\u30b9\u30c6\u30e0\u306f\u3001\u5a92\u4f53\u3068\u306e\u71b1\u5e73\u8861\u306b\u9054\u3059\u308b\u307e\u3067\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002\u3088\u308a\u5c0f\u3055\u306a\u30b9\u30c6\u30e0\u306f\u5fdc\u7b54\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u8010\u5727\u6027\u3001\u6469\u8017\u3001\u8150\u98df\u3001\u304a\u3088\u3073\u6a5f\u68b0\u7684\u5f37\u5ea6\u3082\u8a55\u4fa1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n\n\n\n<p>\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8\u3092\u6bd4\u8f03\u3059\u308b\u969b\u306f\u3001\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u5fdc\u7b54\u6642\u9593\u304c\u30bb\u30f3\u30b7\u30f3\u30b0\u7d20\u5b50\u5358\u4f53\u306b\u5bfe\u3059\u308b\u3082\u306e\u304b\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u542b\u3080\u30a2\u30bb\u30f3\u30d6\u30ea\u5168\u4f53\u306b\u5bfe\u3059\u308b\u3082\u306e\u304b\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306f\u7570\u306a\u308b\u69cb\u6210\u3067\u3042\u308a\u3001\u305d\u308c\u305e\u308c\u306e\u8a66\u9a13\u7d50\u679c\u3092\u305d\u306e\u307e\u307e\u8a2d\u7f6e\u306b\u9069\u7528\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"immersion-depth\"><span class=\"ez-toc-section\" id=\"cause-3-insufficient-immersion-or-an-unsuitable-measuring-position\"><\/span>\u539f\u56e0\uff13\uff1aImmersion\u4e0d\u8db3\u307e\u305f\u306f\u4e0d\u9069\u5207\u306a\u6e2c\u5b9a\u4f4d\u7f6e<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u30a2\u30af\u30c6\u30a3\u30d6\u30bb\u30f3\u30b7\u30f3\u30b0\u30be\u30fc\u30f3\u304c\u4ee3\u8868\u7684\u306a\u30d7\u30ed\u30bb\u30b9\u5a92\u4f53\u306b\u9069\u5207\u306b\u6d78\u6f2c\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3001\u914d\u7ba1\u58c1\u3084\u5468\u56f2\u306e\u7a7a\u6c17\u306b\u3088\u3063\u3066\u6e2c\u5b9a\u5024\u304c\u5f71\u97ff\u3092\u53d7\u3051\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6e2c\u5b9a\u5024\u304c\u9ad8\u304f\u306a\u3063\u305f\u308a\u4f4e\u304f\u306a\u3063\u305f\u308a\u3057\u3066\u3001\u30d7\u30ed\u30bb\u30b9\u5909\u5316\u306e\u691c\u51fa\u304c\u9045\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u306d\u3058\u5c71\u304c\u3074\u3063\u305f\u308a\u5408\u3046\u304b\u3089\u3068\u3044\u3063\u3066\u3001\u30bb\u30f3\u30b7\u30f3\u30b0\u4f4d\u7f6e\u304c\u6b63\u3057\u3044\u3068\u306f\u9650\u308a\u307e\u305b\u3093\u3002.<\/p>\n\n\n\n<p>immersion \u306e\u6df1\u3055\u306f\u3001\u30e1\u30fc\u30ab\u30fc\u306e\u8981\u4ef6\u3001\u30a2\u30af\u30c6\u30a3\u30d6\u30bb\u30f3\u30b7\u30f3\u30b0\u9577\u3001\u30d1\u30a4\u30d7\u5f84\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u5bf8\u6cd5\u304b\u3089\u6c7a\u5b9a\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u6e29\u5ea6\u8a08\u306b\u5171\u901a\u306e\u6df1\u3055\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u7570\u306a\u308b\u8996\u91ce\u89d2\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001 <a href=\"https:\/\/www.sj-gauge.com\/ja\/product\/mtb-s-ba\/\" target=\"_blank\" rel=\"noopener\">MTB.S_BA \u89d2\u5ea6\u8abf\u6574\u53ef\u80fd\u306a\u30d0\u30a4\u30e1\u30bf\u30eb\u6e29\u5ea6\u8a08<\/a> \u5fc5\u8981\u306a\u30bb\u30f3\u30b7\u30f3\u30b0\u4f4d\u7f6e\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u691c\u8a0e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\" style=\"width:640px;max-width:100%;margin:32px auto\"><img decoding=\"async\" width=\"2560\" height=\"1440\" src=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-scaled.jpg\" alt=\"Adjustable-angle thermometer showing its sensing stem and threaded connection\" class=\"wp-image-5966\" style=\"display:block;width:100%;height:auto;aspect-ratio:3\/2;object-fit:cover;object-position:center\" srcset=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-scaled.jpg 2560w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-300x169.jpg 300w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-1024x576.jpg 1024w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-768x432.jpg 768w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-1536x864.jpg 1536w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-2048x1152.jpg 2048w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-18x10.jpg 18w, https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-adjustable-thermometer-stem-and-connection-600x338.jpg 600w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><figcaption class=\"wp-element-caption\">\u56f33\uff5c\u30bb\u30f3\u30b7\u30f3\u30b0\u30b9\u30c6\u30e0\u3068\u63a5\u7d9a\u90e8\u3002\u30a2\u30af\u30c6\u30a3\u30d6\u30bb\u30f3\u30b7\u30f3\u30b0\u9577\u3001immersion\u6df1\u3055\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u9069\u5408\u6027\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"medium-flow\"><span class=\"ez-toc-section\" id=\"cause-4-low-flow-or-a-stagnant-measuring-point\"><\/span>\u539f\u56e04\uff1a\u6d41\u91cf\u4e0d\u8db3\u307e\u305f\u306f\u6e2c\u5b9a\u30dd\u30a4\u30f3\u30c8\u306e\u505c\u6ede<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u5fdc\u7b54\u6642\u9593\u306f\u3001\u5a92\u4f53\u304c\u71b1\u3092\u6e2c\u5b9a\u70b9\u306b\u3069\u308c\u3060\u3051\u52b9\u7387\u7684\u306b\u4f1d\u9054\u3059\u308b\u304b\u306b\u3082\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002\u5bb9\u5668\u5185\u306e\u505c\u6ede\u9818\u57df\u3001\u4e0d\u5341\u5206\u306a\u6df7\u5408\u3001\u4f4e\u6d41\u91cf\u914d\u7ba1\u3001\u7c98\u6027\u5a92\u4f53\u306a\u3069\u306f\u3001\u3044\u305a\u308c\u3082\u6e29\u5ea6\u5909\u5316\u304c\u6e2c\u5b9a\u70b9\u306b\u5230\u9054\u3059\u308b\u306e\u3092\u9045\u3089\u305b\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u6c17\u4f53\u306b\u304a\u3051\u308b\u5fdc\u7b54\u6642\u9593\u3068\u6d41\u52d5\u3059\u308b\u6db2\u4f53\u306b\u304a\u3051\u308b\u5fdc\u7b54\u6642\u9593\u3092\u76f4\u63a5\u6bd4\u8f03\u3059\u3079\u304d\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n\n\n\n<p>\u8a08\u6e2c\u5668\u3092\u4ea4\u63db\u3059\u308b\u524d\u306b\u3001\u6e2c\u5b9a\u4f4d\u7f6e\u304c\u30d7\u30ed\u30bb\u30b9\u6e29\u5ea6\u3092\u6b63\u78ba\u306b\u53cd\u6620\u3057\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4f4d\u7f6e\u3084\u6d41\u91cf\u6761\u4ef6\u3092\u5909\u66f4\u3059\u308b\u5834\u5408\u306f\u3001\u305d\u308c\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u6d41\u4f53\u529b\u3084\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306b\u304a\u3051\u308b\u632f\u52d5\u30ea\u30b9\u30af\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"thermowell\"><span class=\"ez-toc-section\" id=\"cause-5-heat-transfer-through-the-thermowell\"><\/span>\u539f\u56e0\uff15\uff1a\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u901a\u3058\u305f\u71b1\u4f1d\u9054<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306f\u30d7\u30ed\u30bb\u30b9\u5a92\u4f53\u3092\u9694\u96e2\u3057\u3001\u30bb\u30f3\u30b7\u30f3\u30b0\u30b9\u30c6\u30e0\u3092\u4fdd\u8b77\u3057\u307e\u3059\u304c\u3001\u71b1\u4f1d\u9054\u7d4c\u8def\u3092\u8ffd\u52a0\u3059\u308b\u305f\u3081\u3001\u901a\u5e38\u306f\u30a2\u30bb\u30f3\u30d6\u30ea\u306e\u5fdc\u7b54\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u5f71\u97ff\u306f\u3001\u6750\u8cea\u3001\u58c1\u539a\u3001\u5148\u7aef\u5f62\u72b6\u3001\u304a\u3088\u3073\u30b9\u30c6\u30e0\u3068\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u5d4c\u5408\u72b6\u614b\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002.<\/p>\n\n\n\n<p>\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001 <a href=\"https:\/\/www.sj-gauge.com\/ja\/product\/twc\/\" target=\"_blank\" rel=\"noopener\">TWC\u306d\u3058\u8fbc\u307f\u5f0f\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb<\/a>, \u30d7\u30ed\u30bb\u30b9\u63a5\u7d9a\u90e8\u3001\u30dc\u30a2\u5f84\u3001\u6709\u52b9\u6df1\u3055\u3001\u30bb\u30f3\u30b7\u30f3\u30b0\u30b9\u30c6\u30e0\u306e\u5bf8\u6cd5\u3092\u307e\u3068\u3081\u3066\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5fdc\u7b54\u6642\u9593\u304c\u6307\u5b9a\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u88fd\u9020\u5143\u306b\u69cb\u6210\u5168\u4f53\u306e\u8a55\u4fa1\u3092\u4f9d\u983c\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u627f\u8a8d\u3055\u308c\u305f\u8a2d\u8a08\u306a\u3057\u306b\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u8584\u304f\u3057\u305f\u308a\u3001\u71b1\u4f1d\u5c0e\u6027\u30b3\u30f3\u30d1\u30a6\u30f3\u30c9\u3092\u8ffd\u52a0\u3057\u305f\u308a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"improve-response\"><span class=\"ez-toc-section\" id=\"how-can-you-improve-an-industrial-thermometers-response\"><\/span>\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u5fdc\u7b54\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u75c7\u72b6\u3092\u7279\u5b9a\u3059\u308b\uff1a\u540c\u3058\u5834\u6240\u3068\u6642\u9593\u3067\u57fa\u6e96\u6e2c\u5b9a\u5024\u3092\u4f7f\u7528\u3057\u3001\u52a0\u71b1\u6642\u3001\u51b7\u5374\u6642\u3001\u304a\u3088\u3073\u5b89\u5b9a\u904b\u8ee2\u6642\u306e\u6e2c\u5b9a\u5024\u3092\u8a18\u9332\u3059\u308b\u3002.<\/li>\n\n\n\n<li>\u8a2d\u7f6e\u72b6\u6cc1\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30a2\u30af\u30c6\u30a3\u30d6\u30bb\u30f3\u30b7\u30f3\u30b0\u30be\u30fc\u30f3\u3001immersion\u306e\u6df1\u3055\u3001\u6e2c\u5b9a\u4f4d\u7f6e\u3001\u304a\u3088\u3073\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u5185\u3078\u306e\u9069\u5408\u6027\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/li>\n\n\n\n<li>\u8981\u4ef6\u3092\u5b9a\u7fa9\u3057\u307e\u3059\u3002\u8a31\u5bb9\u3055\u308c\u308b\u9045\u5ef6\u6642\u9593\u3068\u3001\u6e2c\u5b9a\u5024\u304c\u30ed\u30fc\u30ab\u30eb\u8868\u793a\u3001\u5236\u5fa1\u3001\u307e\u305f\u306f\u8b66\u5831\u306e\u3044\u305a\u308c\u306b\u4f7f\u7528\u3055\u308c\u308b\u304b\u3092\u660e\u8a18\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/li>\n\n\n\n<li>\u30a2\u30bb\u30f3\u30d6\u30ea\u5168\u4f53\u3092\u8a55\u4fa1\u3057\u3001\u5727\u529b\u3001\u8150\u98df\u3001\u6a5f\u68b0\u7684\u5f37\u5ea6\u306b\u95a2\u3059\u308b\u8981\u4ef6\u3092\u6e80\u305f\u3057\u306a\u304c\u3089\u3001\u30bb\u30f3\u30b7\u30f3\u30b0\u7d20\u5b50\u3068\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u9078\u5b9a\u3059\u308b\u3002.<\/li>\n\n\n\n<li>\u4e00\u8cab\u3057\u305f\u6761\u4ef6\u4e0b\u3067\u691c\u8a3c\u3059\u308b\uff1a\u540c\u3058\u5a92\u4f53\u3001\u6d41\u91cf\u3001immersion\u306e\u6df1\u3055\u3001\u304a\u3088\u3073\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u69cb\u6210\u3067\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u3002.<\/li>\n<\/ol>\n\n\n\n<p>\u5fdc\u7b54\u6642\u9593\u304ct90\u3068\u6307\u5b9a\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3001\u305d\u308c\u306f\u5168\u6e29\u5ea6\u5909\u5316\u306e90%\u3092\u793a\u3059\u306e\u306b\u5fc5\u8981\u306a\u6642\u9593\u3092\u610f\u5473\u3057\u307e\u3059\u300220\u2103\u304b\u3089100\u2103\u3078\u306e\u5909\u5316\u306e\u5834\u5408\u300190%\u30dd\u30a4\u30f3\u30c8\u306f90\u2103\u3067\u306f\u306a\u304f92\u2103\u3067\u3059\u3002\u898b\u7a4d\u3082\u308a\u3092\u4f9d\u983c\u3059\u308b\u969b\u306f\u3001\u6642\u9593\u5024\u3068\u4f75\u305b\u3066\u8a66\u9a13\u6761\u4ef6\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"standards\"><span class=\"ez-toc-section\" id=\"international-standards-references\"><\/span>\u56fd\u969b\u898f\u683c\u306e\u53c2\u7167<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/temperature-measurement\" target=\"_blank\" rel=\"noopener\">ASME PTC 19.3-2024<\/a>: \u6e2c\u5b9a\u914d\u7f6e\u3092\u898b\u76f4\u3059\u969b\u306e\u3001\u6e29\u5ea6\u6e2c\u5b9a\u65b9\u6cd5\u3001\u6a5f\u5668\u306e\u9078\u5b9a\u304a\u3088\u3073\u4f7f\u7528\u306b\u95a2\u3059\u308b\u53c2\u8003\u8cc7\u6599\u3002.<\/li>\n\n\n\n<li><a href=\"https:\/\/knowledge.bsigroup.com\/products\/dial-thermometers\" target=\"_blank\" rel=\"noopener\">EN 13190:2001<\/a>: \u5de5\u696d\u7528\u30c0\u30a4\u30e4\u30eb\u6e29\u5ea6\u8a08\u306e\u8981\u4ef6\u3068\u8a66\u9a13\u3001\u304a\u3088\u3073\u9078\u5b9a\u3068\u8a2d\u7f6e\u306b\u95a2\u3059\u308b\u63a8\u5968\u4e8b\u9805\u3002.<\/li>\n\n\n\n<li><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/b40-200-thermometers-direct-reading-remote-reading\" target=\"_blank\" rel=\"noopener\">ASME B40.200<\/a>: \u30d0\u30a4\u30e1\u30bf\u30eb\u5f0f\u6e29\u5ea6\u8a08\u3001\u5145\u586b\u5f0f\u6e29\u5ea6\u8a08\u3001\u30ac\u30e9\u30b9\u7ba1\u5f0f\u6e29\u5ea6\u8a08\u306a\u3069\u306b\u95a2\u3059\u308b\u7528\u8a9e\u3001\u69cb\u9020\u3001\u8a2d\u7f6e\u3001\u8a66\u9a13\u306b\u95a2\u3059\u308b\u30ac\u30a4\u30c0\u30f3\u30b9\u3002.<\/li>\n\n\n\n<li><a href=\"https:\/\/www.asme.org\/codes-standards\/find-codes-standards\/thermowells\" target=\"_blank\" rel=\"noopener\">ASME PTC 19.3 TW-2016 (R2025)<\/a>\u3053\u308c\u306f\u3001\u305d\u306e\u9069\u7528\u7bc4\u56f2\u5185\u306b\u3042\u308bbar\u30b9\u30c8\u30c3\u30af\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u6a5f\u68b0\u8a2d\u8a08\u306b\u95a2\u3059\u308b\u53c2\u8003\u8cc7\u6599\u3067\u3059\u3002\u30d7\u30ed\u30bb\u30b9\u30b9\u30c8\u30ea\u30fc\u30e0\u306b\u5bfe\u3059\u308b\u30bb\u30f3\u30b5\u30fc\u306e\u71b1\u5e73\u8861\u306f\u8003\u616e\u3055\u308c\u3066\u304a\u3089\u305a\u3001\u305d\u308c\u81ea\u4f53\u3067\u306f\u8a31\u5bb9\u53ef\u80fd\u306a\u5fdc\u7b54\u6642\u9593\u3092\u793a\u3059\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002.<\/li>\n<\/ul>\n\n\n\n<p>\u6a5f\u5668\u3001\u30d7\u30ed\u30bb\u30b9\u3001\u304a\u3088\u3073\u8cfc\u5165\u4ed5\u69d8\u66f8\u3068\u7167\u3089\u3057\u5408\u308f\u305b\u3066\u3001\u9069\u7528\u7bc4\u56f2\u3068\u7248\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u898f\u683c\u3092\u53c2\u7167\u3057\u305f\u304b\u3089\u3068\u3044\u3063\u3066\u3001\u88fd\u54c1\u304c\u81ea\u52d5\u7684\u306b\u8a8d\u8a3c\u3055\u308c\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\"><span class=\"ez-toc-section\" id=\"frequently-asked-questions\"><\/span>\u3088\u304f\u3042\u308b\u8cea\u554f<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u53cd\u5fdc\u304c\u9045\u3044\u3068\u3044\u3046\u3053\u3068\u306f\u3001\u6e29\u5ea6\u8a08\u306e\u7cbe\u5ea6\u304c\u4f4e\u3044\u3068\u3044\u3046\u3053\u3068\u3067\u3057\u3087\u3046\u304b\uff1f<\/h3>\n\n\n\n<p>\u5fc5\u305a\u3057\u3082\u305d\u3046\u3068\u306f\u9650\u308a\u307e\u305b\u3093\u3002\u5fdc\u7b54\u304c\u9045\u3044\u3068\u3044\u3046\u306e\u306f\u3001\u6e29\u5ea6\u5909\u5316\u306b\u4f34\u3046\u9045\u5ef6\u306e\u3053\u3068\u3067\u3059\u3002\u6700\u7d42\u7684\u306a\u6e2c\u5b9a\u5024\u306f\u8a31\u5bb9\u8aa4\u5dee\u306e\u7bc4\u56f2\u5185\u3067\u3042\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5b89\u5b9a\u5f8c\u3082\u9ad8\u3044\u5024\u307e\u305f\u306f\u4f4e\u3044\u5024\u304c\u7d9a\u304f\u5834\u5408\u306f\u3001\u8a2d\u7f6e\u3068\u6821\u6b63\u3092\u305d\u308c\u305e\u308c\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u3092\u53d6\u308a\u5916\u3059\u65b9\u304c\u5e38\u306b\u826f\u3044\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/h3>\n\n\n\n<p>\u71b1\u4f1d\u9054\u7d4c\u8def\u3092\u77ed\u7e2e\u3059\u308b\u3053\u3068\u3067\u5fdc\u7b54\u6027\u304c\u5411\u4e0a\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u30d7\u30ed\u30bb\u30b9\u9694\u96e2\u6a5f\u80fd\u3068\u6a5f\u68b0\u7684\u4fdd\u8b77\u6a5f\u80fd\u304c\u5931\u308f\u308c\u307e\u3059\u3002\u9ad8\u5727\u3001\u8150\u98df\u6027\u3001\u6469\u8017\u6027\u3001\u307e\u305f\u306f\u9ad8\u901f\u6d41\u306e\u74b0\u5883\u3067\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u53d6\u308a\u5916\u3059\u524d\u306b\u8a2d\u8a08\u8981\u4ef6\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\"><span class=\"ez-toc-section\" id=\"conclusion\"><\/span>\u307e\u3068\u3081<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u5fdc\u7b54\u304c\u9045\u3044\u5834\u5408\u306f\u3001\u691c\u51fa\u539f\u7406\u3001\u5bf8\u6cd5\u3001immersion\u306e\u6df1\u3055\u3001\u6d41\u91cf\u6761\u4ef6\u3001\u304a\u3088\u3073\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u9069\u5408\u6027\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30d7\u30ed\u30bb\u30b9\u3067\u6e2c\u5b9a\u306b\u6c42\u3081\u3089\u308c\u308b\u5fdc\u7b54\u901f\u5ea6\u3092\u5b9a\u7fa9\u3057\u3001\u305d\u306e\u8981\u4ef6\u306b\u5bfe\u3057\u3066\u30a2\u30bb\u30f3\u30d6\u30ea\u5168\u4f53\u3092\u691c\u8a3c\u3057\u3066\u304f\u3060\u3055\u3044\u3002.<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.sj-gauge.com\/ja\/contact\/\" target=\"_blank\" rel=\"noopener\">SJ Gauge\u3078\u304a\u554f\u3044\u5408\u308f\u305b<\/a> \u5a92\u4f53\u3001\u52d5\u4f5c\u6e29\u5ea6\u3068\u5727\u529b\u3001\u6d41\u901f\u3001\u30d1\u30a4\u30d7\u5f84\u3001\u73fe\u5728\u306e\u30b9\u30c6\u30e0\u3068\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u306e\u5bf8\u6cd5\u3092\u304a\u77e5\u3089\u305b\u304f\u3060\u3055\u3044\u3002\u5fc5\u8981\u306a\u5fdc\u7b54\u6642\u9593\u3082\u4f75\u305b\u3066\u3054\u63d0\u4f9b\u3044\u305f\u3060\u3051\u308c\u3070\u3001\u5f0a\u793e\u30c1\u30fc\u30e0\u304c\u6700\u9069\u306a\u69cb\u6210\u3092\u8a55\u4fa1\u3044\u305f\u3057\u307e\u3059\u3002.<\/strong><\/p>\n\n\n\n<p><strong>\u3055\u3089\u306b\u8aad\u3080\uff1a<\/strong> <a href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-inaccurate-reading\/\" target=\"_blank\" rel=\"noopener\">\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u8aad\u307f\u53d6\u308a\u5024\u304c\u4e0d\u6b63\u78ba\u306a\u5834\u5408\uff1aImmersion\u306e\u6df1\u3055\u3068\u53d6\u308a\u4ed8\u3051\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>When equipment heats up, the thermometer pointer may take time to follow. During cooling, the reading may also remain high for a while. This does not necessarily indicate a fault: heat takes time to pass from the medium to the sensing element, and the stem, installation position and thermowell all affect that delay. First check whether a significant difference remains after the process temperature stabilizes. This helps distinguish a response that is too slow for the process from a persistent measurement error. Where rapid monitoring is required, specify the response time of the complete installed assembly as well as its range and accuracy. Cause 1: Different Sensing Principles and Designs [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5980,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[61],"tags":[72],"class_list":["post-5974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","tag-temperature"],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.7 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Slow Thermometer Response: 5 Causes &amp; Fixes\u306b\u3064\u3044\u3066\uff5cSJ Gauge<\/title>\n<meta name=\"description\" content=\"Learn why industrial thermometers respond slowly and how sensor design, stem size, immersion depth, flow and thermowells affect response time.\u306b\u3064\u3044\u3066\u3001SJ Gaug\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Is Your Industrial Thermometer Slow to\u3002\u306b\u3064\u3044\u3066\uff5cSJ Gauge\" \/>\n<meta property=\"og:description\" content=\"Learn why industrial thermometers respond slowly and how sensor design, stem size, immersion depth, flow and thermowells affect response time.\u306b\u3064\u3044\u3066\u3001SJ Gaug\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/\" \/>\n<meta property=\"og:site_name\" content=\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-18T07:37:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-18T07:56:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2400\" \/>\n\t<meta property=\"og:image:height\" content=\"1256\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"SJ Gauge\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"SJ Gauge\u306e\u88fd\u54c1\u30fb\u6280\u8853\u60c5\u5831\u306b\u3064\u3044\u3066\uff5cSJ Gauge\" \/>\n<meta name=\"twitter:description\" content=\"\u3053\u306e\u30da\u30fc\u30b8\u306b\u3064\u3044\u3066\u3001SJ Gauge\u306e\u88fd\u54c1\u30fb\u6280\u8853\u60c5\u5831\u3092\u3054\u6848\u5185\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"SJ Gauge\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/\"},\"author\":{\"name\":\"SJ Gauge\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\"},\"headline\":\"Why Is Your Industrial Thermometer Slow to Respond? 5 Causes and Solutions\",\"datePublished\":\"2026-09-18T07:37:35+00:00\",\"dateModified\":\"2026-09-18T07:56:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/\"},\"wordCount\":1064,\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/sj-industrial-thermometer-sensing-stem-response.jpg\",\"keywords\":[\"Temperature\"],\"articleSection\":[\"Knowledge\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/\",\"name\":\"Slow Thermometer Response: 5 Causes & Fixes | SJ Gauge\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/sj-industrial-thermometer-sensing-stem-response.jpg\",\"datePublished\":\"2026-09-18T07:37:35+00:00\",\"dateModified\":\"2026-09-18T07:56:27+00:00\",\"description\":\"Learn why industrial thermometers respond slowly and how sensor design, stem size, immersion depth, flow and thermowells affect response time.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/sj-industrial-thermometer-sensing-stem-response.jpg\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/sj-industrial-thermometer-sensing-stem-response.jpg\",\"width\":2400,\"height\":1256,\"caption\":\"Figure 1 | Sensing stem and threaded connection of an industrial thermometer. Stem dimensions and installation conditions affect how quickly temperature changes reach the sensing element.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/industrial-thermometer-slow-response\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sj-gauge.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why Is Your Industrial Thermometer Slow to Respond? 5 Causes and Solutions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"name\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\",\"description\":\"Manufacturer of industrial pressure gauges, pressure sensors, and transmitters. SJ Gauge provides high accuracy, durable materials, and custom solutions for oil &amp; gas, chemical, and industrial applications.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sj-gauge.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\",\"name\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"width\":348,\"height\":184,\"caption\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\",\"name\":\"SJ Gauge\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/litespeed\\\/avatar\\\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/litespeed\\\/avatar\\\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/litespeed\\\/avatar\\\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420\",\"caption\":\"SJ Gauge\"},\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/ja\\\/author\\\/sj-gauge\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Slow Thermometer Response: 5 Causes & Fixes\u306b\u3064\u3044\u3066\uff5cSJ Gauge","description":"Learn why industrial thermometers respond slowly and how sensor design, stem size, immersion depth, flow and thermowells affect response time.\u306b\u3064\u3044\u3066\u3001SJ Gaug\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/","og_locale":"ja_JP","og_type":"article","og_title":"Why Is Your Industrial Thermometer Slow to\u3002\u306b\u3064\u3044\u3066\uff5cSJ Gauge","og_description":"Learn why industrial thermometers respond slowly and how sensor design, stem size, immersion depth, flow and thermowells affect response time.\u306b\u3064\u3044\u3066\u3001SJ Gaug\u3002","og_url":"https:\/\/www.sj-gauge.com\/ja\/industrial-thermometer-slow-response\/","og_site_name":"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors","article_published_time":"2026-09-18T07:37:35+00:00","article_modified_time":"2026-09-18T07:56:27+00:00","og_image":[{"width":2400,"height":1256,"url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg","type":"image\/jpeg"}],"author":"SJ Gauge","twitter_card":"summary_large_image","twitter_title":"SJ Gauge\u306e\u88fd\u54c1\u30fb\u6280\u8853\u60c5\u5831\u306b\u3064\u3044\u3066\uff5cSJ Gauge","twitter_description":"\u3053\u306e\u30da\u30fc\u30b8\u306b\u3064\u3044\u3066\u3001SJ Gauge\u306e\u88fd\u54c1\u30fb\u6280\u8853\u60c5\u5831\u3092\u3054\u6848\u5185\u3057\u307e\u3059\u3002","twitter_misc":{"\u57f7\u7b46\u8005":"SJ Gauge","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#article","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/"},"author":{"name":"SJ Gauge","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c"},"headline":"Why Is Your Industrial Thermometer Slow to Respond? 5 Causes and Solutions","datePublished":"2026-09-18T07:37:35+00:00","dateModified":"2026-09-18T07:56:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/"},"wordCount":1064,"publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"image":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg","keywords":["Temperature"],"articleSection":["Knowledge"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/","url":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/","name":"\u6e29\u5ea6\u8a08\u306e\u53cd\u5fdc\u304c\u9045\u3044\uff1a5\u3064\u306e\u539f\u56e0\u3068\u89e3\u6c7a\u7b56 | SJ Gauge","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#primaryimage"},"image":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg","datePublished":"2026-09-18T07:37:35+00:00","dateModified":"2026-09-18T07:56:27+00:00","description":"\u5de5\u696d\u7528\u6e29\u5ea6\u8a08\u306e\u5fdc\u7b54\u304c\u9045\u3044\u7406\u7531\u3068\u3001\u30bb\u30f3\u30b5\u30fc\u306e\u8a2d\u8a08\u3001\u30b9\u30c6\u30e0\u306e\u30b5\u30a4\u30ba\u3001immersion\u306e\u6df1\u3055\u3001\u6d41\u91cf\u3001\u30b5\u30fc\u30e2\u30a6\u30a7\u30eb\u304c\u5fdc\u7b54\u6642\u9593\u306b\u3069\u306e\u3088\u3046\u306b\u5f71\u97ff\u3059\u308b\u304b\u3092\u5b66\u3073\u307e\u3057\u3087\u3046\u3002.","breadcrumb":{"@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#primaryimage","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/09\/sj-industrial-thermometer-sensing-stem-response.jpg","width":2400,"height":1256,"caption":"Figure 1 | Sensing stem and threaded connection of an industrial thermometer. Stem dimensions and installation conditions affect how quickly temperature changes reach the sensing element."},{"@type":"BreadcrumbList","@id":"https:\/\/www.sj-gauge.com\/industrial-thermometer-slow-response\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sj-gauge.com\/es\/"},{"@type":"ListItem","position":2,"name":"Why Is Your Industrial Thermometer Slow to Respond? 5 Causes and Solutions"}]},{"@type":"WebSite","@id":"https:\/\/www.sj-gauge.com\/#website","url":"https:\/\/www.sj-gauge.com\/","name":"SJ Gauge\uff5c \u5727\u529b\u8a08\u3001\u6e29\u5ea6\u8a08\u3001\u5727\u529b\u30bb\u30f3\u30b5","description":"\u5de5\u696d\u7528\u5727\u529b\u8a08\u3001\u5727\u529b\u30bb\u30f3\u30b5\u3001\u30c8\u30e9\u30f3\u30b9\u30df\u30c3\u30bf\u306e\u30e1\u30fc\u30ab\u30fc\u3002SJ Gauge\u306f\u3001\u30aa\u30a4\u30eb\uff06\u30ac\u30b9\u3001\u5316\u5b66\u3001\u7523\u696d\u7528\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u5411\u3051\u306b\u3001\u9ad8\u7cbe\u5ea6\u3001\u8010\u4e45\u6027\u306e\u3042\u308b\u6750\u6599\u3001\u30ab\u30b9\u30bf\u30e0\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002","publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sj-gauge.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/www.sj-gauge.com\/#organization","name":"SJ Gauge\uff5c \u5727\u529b\u8a08\u3001\u6e29\u5ea6\u8a08\u3001\u5727\u529b\u30bb\u30f3\u30b5","url":"https:\/\/www.sj-gauge.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","width":348,"height":184,"caption":"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors"},"image":{"@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c","name":"SJ Gauge","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.sj-gauge.com\/wp-content\/litespeed\/avatar\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420","url":"https:\/\/www.sj-gauge.com\/wp-content\/litespeed\/avatar\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/litespeed\/avatar\/b325a50a2f5f3f919eda58ee6d7a47ae.jpg?ver=1789362420","caption":"SJ Gauge"},"url":"https:\/\/www.sj-gauge.com\/ja\/author\/sj-gauge\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/posts\/5974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/comments?post=5974"}],"version-history":[{"count":5,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/posts\/5974\/revisions"}],"predecessor-version":[{"id":5981,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/posts\/5974\/revisions\/5981"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/media\/5980"}],"wp:attachment":[{"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/media?parent=5974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/categories?post=5974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/ja\/wp-json\/wp\/v2\/tags?post=5974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}