{"id":2683,"date":"2022-08-13T13:52:35","date_gmt":"2022-08-13T05:52:35","guid":{"rendered":"https:\/\/sj-gauge.com\/?p=2683"},"modified":"2026-04-25T22:16:55","modified_gmt":"2026-04-25T14:16:55","slug":"dial-thermometer-accuracy","status":"publish","type":"post","link":"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/","title":{"rendered":"\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\u7b49\u7d1a\u8207\u5176\u5bb9\u8a31\u8aa4\u5dee\uff0c\u5982\u4f55\u6821\u6b63\u6eab\u5ea6\u8a08\uff1f"},"content":{"rendered":"<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u6e96\u78ba\u6027\u5c0d\u5de5\u696d\u88fd\u7a0b\u548c\u6c7a\u7b56\u81f3\u95dc\u91cd\u8981\uff01<\/strong><\/p>\n\n\n\n<p>\u53ef\u60dc\u7684\u662f\uff0c\u5728\u6211\u5011\u65e5\u5e38\u4f7f\u7528\u6eab\u5ea6\u6e2c\u91cf\u5de5\u5177\u6642\uff0c\u9019\u500b\u91cd\u8981\u6b65\u9a5f\u5e38\u5e38\u88ab\u5ffd\u7565\u3002 \u4eba\u5011\u50be\u5411\u65bc\u76f8\u4fe1\u6eab\u5ea6\u611f\u6e2c\u5100\u5668\u7e3d\u662f\u6b63\u78ba\u7121\u8aa4\uff0c\u4f46\u9019\u662f\u4e00\u500b\u932f\u8aa4\u3002<\/p>\n\n\n\n<p>\u7121\u8ad6\u662f\u5728\u80fd\u6e90\u4f9b\u61c9\u3001\u91ab\u7642\u548c\u98df\u54c1\u6280\u8853\u3001\u5316\u5b78\u548c\u88fd\u85e5\u884c\u696d\uff0c\u9084\u662f\u5728\u8239\u8236\u548c\u6c7d\u8eca\u9818\u57df\uff0c\u6b63\u78ba\u3001\u53ef\u9760\u7684\u6eab\u5ea6\u6e2c\u91cf\u5728\u6240\u6709\u56b4\u683c\u8981\u6c42\u7684\u904e\u7a0b\u4e2d\u90fd\u662f\u4e0d\u53ef\u6216\u7f3a\u7684\u3002<\/p>\n\n\n\n<p>\u56e0\u6b64\uff0c\u7576\u5c0d\u65bc\u6e2c\u6eab\u5100\u9336\u7684\u7cbe\u5ea6\u6709\u7591\u616e\u6642\uff0c\u5c31\u9700\u8981\u7531\u5c08\u696d\u7684\u5100\u9336\u4f9b\u61c9\u5546\u9032\u884c\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u6821\u6b63\u3002<\/p>\n\n\n\n<p><strong>\u60a8\u60f3\u6df1\u5165\u4e86\u89e3\u5982\u4f55\u9032\u884c\u6307\u91dd\u578b\u6eab\u5ea6\u5100\u5668\u7684\u6821\u6b63\u55ce\uff1f<\/strong><\/p>\n\n\n\n<p>\u5728\u63a5\u4e0b\u4f86\u7684\u5167\u5bb9\u4e2d\uff0cSJ \u7098\u73c8\u5100\u9336\u5c07\u4ecb\u7d39\u6307\u91dd\u578b\u6eab\u5ea6\u5100\u5668\u7684\u7cbe\u5ea6\u7b49\u7d1a\u548c\u5bb9\u8a31\u8aa4\u5dee\u3002\u89e3\u91cb\u70ba\u4f55\u6eab\u5ea6\u5100\u5668\u9700\u8981\u7d93\u904e\u6821\u6b63\uff0c\u900f\u904e\u7c21\u55ae\u6613\u61c2\u7684\u7bc4\u4f8b\uff0c\u5354\u52a9\u60a8\u66f4\u5168\u9762\u5730\u7406\u89e3\u6eab\u5ea6\u8a08\u7684\u6821\u6b63\u904e\u7a0b\u3002<\/p>\n\n\n\n<p>\u5982\u679c\u60a8\u5c0d\u6b64\u6709\u8208\u8da3\uff0c\u8acb\u7e7c\u7e8c\u95b1\u8b80\u6211\u5011\u7684\u6587\u7ae0\uff0c\u6216\u76f4\u63a5\u806f\u7e6b\u6211\u5011\u3002SJ \u7098\u73c8\u5100\u9336\u7684\u5c08\u696d\u92b7\u552e\u5718\u968a\u96a8\u6642\u70ba\u60a8\u7684\u61c9\u7528\u63d0\u4f9b\u6700\u9069\u5408\u7684\u6eab\u5ea6\u91cf\u6e2c\u89e3\u6c7a\u65b9\u6848\uff01<\/p>\n<\/blockquote>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u76ee\u9304<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u986f\u793a\/\u96b1\u85cf\u5167\u5bb9\u76ee\u9304\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u5207\u63db<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #7b1e1c;color:#7b1e1c\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #7b1e1c;color:#7b1e1c\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/#1-what-does-%e2%80%9caccuracy%e2%80%9d-mean-in-dial-thermometers-understanding-the-definitions-of-terms-related-to-temperature-calibration\" >1.\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u7684\u7cbe\u5ea6\u662f\u4ec0\u9ebc\u610f\u601d\uff1f\u7cbe\u5ea6\u76f8\u95dc\u540d\u8a5e\u5b9a\u7fa9\u70ba\u4f55\uff1f<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/#2-what-is-temperature-calibration-why-do-thermometers-need-calibration\" >2. \u70ba\u4ec0\u9ebc\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u9700\u8981\u6821\u6b63\uff1f\u6eab\u5ea6\u6821\u6b63\u8a72\u5982\u4f55\u9032\u884c\uff1f<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/#3-how-should-temperature-calibration-be-conducted\" >3. \u6eab\u5ea6\u6821\u6b63\u8a72\u5982\u4f55\u9032\u884c\uff1f<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-87025ba603ab1861b355e85ef744b865\"><span class=\"ez-toc-section\" id=\"1-what-does-%e2%80%9caccuracy%e2%80%9d-mean-in-dial-thermometers-understanding-the-definitions-of-terms-related-to-temperature-calibration\"><\/span>1.\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u7684\u7cbe\u5ea6\u662f\u4ec0\u9ebc\u610f\u601d\uff1f\u7cbe\u5ea6\u76f8\u95dc\u540d\u8a5e\u5b9a\u7fa9\u70ba\u4f55\uff1f<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">a. \u7cbe\u5ea6\uff08Accuracy\uff09<br>\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\uff08Accuracy\uff09\u662f\u4ec0\u9ebc\u610f\u601d\uff1f<\/h3>\n\n\n\n<p>\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\uff08Accuracy\uff09\u662f\u6307\u6e2c\u91cf\u6578\u503c\uff08\u89c0\u6e2c\u503c\u6216\u8b80\u503c\uff09\u8207\u5176\u771f\u5be6\u503c\u7684\u63a5\u8fd1\u6216\u504f\u96e2\u7a0b\u5ea6\u3002\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\u6a19\u793a\u9ed8\u8a8d\u55ae\u4f4d\u662f \u2103\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b. \u7cbe\u5ea6\u7b49\u7d1a\uff08Accuracy Class\uff09<br>\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u7684\u7cbe\u5ea6\u7b49\u7d1a\uff08Accuracy Class\uff09\u662f\u4ec0\u9ebc\u610f\u601d\uff1f<\/h3>\n\n\n\n<p>\u6839\u64da BS EN13190:2001\uff08\u82f1\u570b\u6a19\u6e96\uff09\uff0c\u7cbe\u5ea6\u7b49\u7d1a\u5206\u70ba 1 \u7d1a\u548c 2 \u7d1a\u3002\u4e0d\u540c\u7684\u6eab\u5ea6\u7bc4\u570d\uff08\u6eab\u5ea6\u6e2c\u91cf\u7bc4\u570d\uff09\u548c\u523b\u5ea6\u76e4\u76f4\u5f91\u5c0d\u61c9\u4e0d\u540c\u7684\u7cbe\u5ea6\u7b49\u7d1a\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">c. \u5141\u8a31\u8aa4\u5dee\uff08Limits of Error\uff09<\/h3>\n\n\n\n<p>\u6307\u91dd\u578b\u6eab\u5ea6\u8a08\u7684\u6e2c\u91cf\u6578\u503c\u5fc5\u9808\u7b26\u5408\u5141\u8a31\u8aa4\u5dee\u7bc4\u570d\uff0c\u6839\u64da\u4e0d\u540c\u689d\u4ef6\u7684\u6a19\u7a31\u7bc4\u570d\uff08\u9762\u5f91\u7bc4\u570d\uff09\u3001\u6eab\u5ea6\u91cf\u7a0b\uff08\u6eab\u5ea6\u91cf\u6e2c\u7bc4\u570d\uff09\u53ca\u5141\u8a31\u8aa4\u5dee\u3002<\/p>\n\n\n\n<p>\u6eab\u5ea6\u91cf\u7a0b\uff08\u6eab\u5ea6\u91cf\u6e2c\u7bc4\u570d\uff09\u662f\u4f9d\u64da\u60a8\u7684\u61c9\u7528\u4e4b\u5e38\u7528\u6eab\u5ea6\u800c\u5236\u5b9a\u7684\uff0c\u61c9\u81f3\u5c11\u5ef6\u4f38\u81f3\u9336\u9762\u5f91\u7684\u4e09\u5206\u4e4b\u4e8c\uff0c\u5373\u60a8\u7684\u6e2c\u91cf\u7bc4\u570d\u6c38\u9060\u4e0d\u61c9\u8a72\u8d85\u904e\u6a19\u7a31\u7bc4\u570d\uff08\u9762\u5f91\u7bc4\u570d\uff09\u3002<\/p>\n\n\n\n<p>BS EN13190:2001\uff08Britsh Standard\uff09\u7e6a\u6210\u4e0b\u8868\uff0c\u89e3\u8aaa\u5728\u4e0d\u540c\u689d\u4ef6\u4e0b\u7684\u7cbe\u5ea6\u7b49\u7d1a\u53ca\u5141\u8a31\u8aa4\u5dee\u7684\u5c0d\u61c9\u95dc\u4fc2\u3002<\/p>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">\u6a19\u7a31\u7bc4\u570d\n\n\uff08\u9762\u5f91\u7bc4\u570d\uff09\n\n\u2103<\/td><td rowspan=\"2\">\u6eab\u5ea6\u91cf\u7a0b\n\n\uff08\u6eab\u5ea6\u91cf\u6e2c\u7bc4\u570d\uff09\n\n\u2103<\/td><td colspan=\"2\">\u8aa4\u5dee\u7bc4\u570d \u00b1 \u2103<\/td><\/tr><tr><td>\u7b2c\u4e00\u7d1a<\/td><td>\u7b2c\u4e8c\u7d1a<\/td><\/tr><tr><td>-20 ... +40<br>-20 ... +60<br>-20 ... +120<\/td><td>-10 ... +30<br>-10 ... +50<br>-10 ... +110<\/td><td>1<br>1<br>2<\/td><td>2<br>2<br>4<\/td><\/tr><tr><td>-30 ... +30<br>-30 ... +50<br>-30 ... +70<\/td><td>-20 ... +20<br>-20 ... +40<br>-20 ... +60<\/td><td>1<br>1<br>1<\/td><td>2<br>2<br>2<\/td><\/tr><tr><td>-40 ... +40<br>-40 ... +60<br>-100 ... +60<\/td><td>-30 ... +30<br>-30 ... +50<br>-80 ... +40<\/td><td>1<br>1<br>2<\/td><td>2<br>2<br>4<\/td><\/tr><tr><td>0 ... 60<br>0 ... 80<br>0 ... 100<\/td><td>10 ... 50<br>10 ... 70<br>10 ... 90<\/td><td>1<br>1<br>1<\/td><td>2<br>2<br>2<\/td><\/tr><tr><td>0 ... 120<br>0 ... 160<br>0 ... 200<\/td><td>10 ... 110<br>20 ... 140<br>20 ... 180<\/td><td>2<br>2<br>2<\/td><td>4<br>4<br>4<\/td><\/tr><tr><td>0 ... 250<br>0 ... 300<br>0 ... 400<\/td><td>30 ... 220<br>30 ... 270<br>50 ... 350<\/td><td>2.5<br>5<br>5<\/td><td>5<br>10<br>10<\/td><\/tr><tr><td>0 ... 500<br>0 ... 600<br>0 ... 700<\/td><td>50 ... 450<br>100 ... 500<br>100 ... 600<\/td><td>5<br>10<br>10<\/td><td>10<br>15<br>15<\/td><\/tr><tr><td>50 ... 650<br>100 ... 700<\/td><td>150 ... 550<br>200 ... 600<\/td><td>10<br>10<\/td><td>15<br>15<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>* \u6e2c\u91cf\u7bc4\u570d\u81f3\u5c11\u61c9\u5ef6\u4f38\u81f3\u6a19\u7a31\u91cf\u7a0b\u7684\u4e09\u5206\u4e4b\u4e8c\u3002<br>* \u5982\u679c\u984d\u5b9a\u7bc4\u570d\u8d85\u904e\u4e0a\u9650\uff0c\u5247\u61c9\u4f7f\u7528\u4e0b\u4e00\u500b\u6eab\u5ea6\u7bc4\u570d\u3002<\/p>\n\n\n\n<p>\u4f8b\u5982\uff1a,<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u984d\u5b9a\u7bc4\u570d\uff1a0 ... 100 \u2103<\/li>\n\n\n\n<li>\u6e2c\u91cf\u7bc4\u570d\uff1a10 ... 90 \u2103<\/li>\n<\/ul>\n\n\n\n<p>\u6839\u64da\u4e0a\u8868\uff0c\u6578\u503c\u5982\u4e0b\uff1a<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u7b2c\u3127\u7d1a\u8aa4\u5dee\uff1a \u00b1 1 \u2103<\/h4>\n\n\n\n<p>\u9019\u8868\u793a\u7576\u5be6\u969b\u6eab\u5ea6\u70ba 20 \u2103 \u6642\uff0c\u8aa4\u5dee\u7bc4\u570d\u5728 19 ... 21 \u2103 \u4e4b\u9593\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u7b2c\u4e8c\u7d1a\u8aa4\u5dee\uff1a\u00b1 2 \u2103<\/h4>\n\n\n\n<p>\u9019\u8868\u793a\u7576\u5be6\u969b\u6eab\u5ea6\u70ba 20 \u2103 \u6642\uff0c\u8aa4\u5dee\u7bc4\u570d\u5728 18 ... 22 \u2103 \u4e4b\u9593\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-bb934367d7315bdead77fd60ffc892c2\"><span class=\"ez-toc-section\" id=\"2-what-is-temperature-calibration-why-do-thermometers-need-calibration\"><\/span>2. \u70ba\u4ec0\u9ebc\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u9700\u8981\u6821\u6b63\uff1f\u6eab\u5ea6\u6821\u6b63\u8a72\u5982\u4f55\u9032\u884c\uff1f<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u70ba\u4ec0\u9ebc\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u9700\u8981\u6821\u6b63\uff1f<\/h3>\n\n\n\n<p>\u53ef\u9760\u7684\u6e2c\u91cf\u548c\u6b63\u78ba\u7684\u6eab\u5ea6\u6578\u64da\u6709\u52a9\u65bc\u63d0\u9ad8\u751f\u7522\u6548\u7387\uff0c\u964d\u4f4e\u610f\u5916\u505c\u6a5f\u7684\u98a8\u96aa\uff0c\u63d0\u4f9b\u6eff\u8db3\u74b0\u5883\u8981\u6c42\u7684\u57fa\u790e\uff0c\u4e26\u900f\u904e\u66f4\u9ad8\u6548\u7387\u7684\u751f\u7522\u9032\u800c\u512a\u5316\u5229\u6f64\u3002<\/p>\n\n\n\n<p>\u5373\u4f7f\u662f\u6700\u9ad8\u54c1\u8cea\u7684\u6eab\u5ea6\u8a08\u4e5f\u6703\u96a8\u8457\u6642\u9593\u7684\u63a8\u79fb\u800c\u8b8a\u5f97\u4e0d\u90a3\u9ebc\u6e96\u78ba\u3002\u70ba\u4e86\u4fdd\u6301\u5100\u9336\u7684\u6700\u4f73\u53ef\u9760\u6027\uff0c\u5efa\u8b70\u60a8\u53ef\u5b9a\u671f\u9a57\u8b49\u53ca\u9032\u884c\u6821\u6b63\u3002<\/p>\n\n\n\n<p>\u6b64\u5916\uff0c\u6eab\u5ea6\u6e2c\u91cf\u5100\u5668\u901a\u5e38\u5efa\u8b70\u6bcf\u5e74\u9032\u884c\u4e00\u6b21\u6821\u6e96\u3002<\/p>\n\n\n\n<p>\u4e0a\u8ff0\u4efb\u4f55\u4e00\u7a2e\u60c5\u6cc1\u90fd\u53ef\u80fd\u5c0e\u81f4\u89c0\u6e2c\u6578\u64da\u932f\u8aa4\u3002\u6211\u5011\u5efa\u8b70\u5ba2\u6236\u7acb\u5373\u5c07\u5100\u5668\u9001\u81f3\u53ef\u9760\u7684\u4f9b\u61c9\u5546\uff08\u5982 SJ Gauge\uff09\u9032\u884c\u58d3\u529b\u6821\u6b63\u548c\u7dad\u8b77\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-3a4d720e17dc2eb181dc392077d09e4d\"><span class=\"ez-toc-section\" id=\"3-how-should-temperature-calibration-be-conducted\"><\/span>3. \u6eab\u5ea6\u6821\u6b63\u8a72\u5982\u4f55\u9032\u884c\uff1f<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u82f1\u570b\u6a19\u6e96\u6aa2\u9a57\u5c40\u65bcBS EN 13190-2001\u63d0\u51fa\uff1a\u6e2c\u8a66\u61c9\u4f7f\u7528\u7cbe\u5ea6\u81f3\u5c11\u70ba\u88ab\u6e2c\u6eab\u5ea6\u8a08\u7cbe\u5ea6\u56db\u500d\u7684\u6e2c\u8a66\u5100\u5668\u9032\u884c\u3002 \u6e2c\u8a66\u5100\u5668\u61c9\u53ef\u6eaf\u6e90\u81f3\u570b\u5bb6\u5ea6\u91cf\u8861\u6a19\u6e96\u5be6\u9a57\u5ba4\uff0d\u91cf\u6e2c\u8ffd\u6eaf\u9ad4\u7cfb\u6216\u570b\u969b\u5ea6\u91cf\u8861\u76f8\u95dc\u898f\u7bc4\u3002<\/p>\n\n\n\n<p>\u4ee5\u4e0b\u662fBS EN 13190-2001\u63d0\u51fa\u95dc\u65bc\u6307\u91dd\u578b\u6eab\u5ea6\u9336\u6821\u6b63\u7684\u4e09\u7a2e\u5e38\u898b\u6aa2\u6e2c\u65b9\u5f0f\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u63a5\u53d7\u6e2c\u8a66\u7684\u6eab\u5ea6\u5075\u6e2c\u5143\u4ef6\u5fc5\u9808\u66b4\u9732\u5728\u76f8\u5c0d\u61c9\u65bc\u5176\u6700\u5927\u523b\u5ea6\u503c\u6216 +60 \u2103 \u7684\u6eab\u5ea6\u4e0b 20 \u5206\u9418\uff0c\u4ee5\u8f03\u9ad8\u8005\u70ba\u6e96\u3002<\/li>\n\n\n\n<li>\u7136\u5f8c\u61c9\u4f7f\u7528\u5728\u6e2c\u91cf\u7bc4\u570d\u5167\u4ee5\u4e00\u81f4\u9593\u9694\u9078\u53d6\u7684\u81f3\u5c11\u4e09\u500b\u6eab\u5ea6\u5c0d\u6eab\u5ea6\u8a08\u9032\u884c\u6e96\u78ba\u6027\u548c\u6eef\u5f8c\u6e2c\u8a66\u3002\u6e2c\u8a66\u61c9\u5728\u4e0a\u4e0b\u523b\u5ea6\u7684\u53c3\u8003\u689d\u4ef6\u4e0b\u9032\u884c\u3002<\/li>\n\n\n\n<li>\u5982\u679c\u6eab\u5ea6\u8a08\u53ef\u5b89\u88dd\u5728\u4efb\u4f55\u89d2\u5ea6\uff0c\u5247\u61c9\u78ba\u5b9a\u6eab\u5ea6\u8a08\u6cbf\u5176\u7e31\u8ef8\u548c\u6a6b\u8ef8\u8f49 90 \u5ea6\u6642\u7684\u6307\u793a\u8b8a\u5316\u3002<\/li>\n<\/ol>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>\u5343\u5206\u8868\u6eab\u5ea6\u8a08\u7684\u7cbe\u78ba\u5ea6\u5728\u5de5\u696d\u88fd\u7a0b\u548c\u6c7a\u7b56\u904e\u7a0b\u4e2d\u81f3\u95dc\u91cd\u8981\u3002\u7136\u800c\uff0c\u5728\u6211\u5011\u65e5\u5e38\u4f7f\u7528\u6eab\u5ea6\u6e2c\u91cf\u5de5\u5177\u7684\u904e\u7a0b\u4e2d\uff0c\u9019\u500b\u91cd\u8981\u7684\u6b65\u9a5f\u7d93\u5e38\u88ab\u5ffd\u7565\uff0c\u8a31\u591a\u4eba\u4ee5\u70ba\u6eab\u5ea6\u611f\u6e2c\u5668\u7e3d\u662f\u6e96\u78ba\u7121\u8aa4\uff0c\u9019\u662f\u4e00\u500b\u5e38\u898b\u7684\u8aa4\u89e3\u3002\u7121\u8ad6\u662f\u5728\u80fd\u6e90\u4f9b\u61c9\u3001\u91ab\u7642\u8207\u98df\u54c1\u6280\u8853\u3001\u5316\u5b78\u8207\u88fd\u85e5\u7522\u696d\uff0c\u6216\u662f\u822a\u904b\u8207\u6c7d\u8eca\u696d\uff0c [...]<\/p>","protected":false},"author":2,"featured_media":2684,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[61],"tags":[72],"class_list":["post-2683","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","tag-temperature"],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.7 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>The Accuracy Class and Limits of Error of Dial Thermometers - SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/\" \/>\n<meta property=\"og:locale\" content=\"zh_TW\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The Accuracy Class and Limits of Error of Dial Thermometers\" \/>\n<meta property=\"og:description\" content=\"The accuracy of dial thermometers is crucial in industrial processes and decision-making. However, this important step is often overlooked in our daily use of temperature-measuring tools, with many assuming that temperature sensors are always accurate \u2014 a common misconception. Whether in energy supply, medical and food technology, chemical and pharmaceutical industries, or shipping and automotive, [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/\" \/>\n<meta property=\"og:site_name\" content=\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-13T05:52:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-25T14:16:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"SJ Gauge\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005:\" \/>\n\t<meta name=\"twitter:data1\" content=\"SJ Gauge\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9810\u4f30\u95b1\u8b80\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\u9418\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/\"},\"author\":{\"name\":\"SJ Gauge\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\"},\"headline\":\"The Accuracy Class and Limits of Error of Dial Thermometers\",\"datePublished\":\"2022-08-13T05:52:35+00:00\",\"dateModified\":\"2026-04-25T14:16:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/\"},\"wordCount\":723,\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/4-05_BN.jpg\",\"keywords\":[\"Temperature\"],\"articleSection\":[\"Knowledge\"],\"inLanguage\":\"zh-TW\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/\",\"name\":\"The Accuracy Class and Limits of Error of Dial Thermometers - SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/4-05_BN.jpg\",\"datePublished\":\"2022-08-13T05:52:35+00:00\",\"dateModified\":\"2026-04-25T14:16:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#breadcrumb\"},\"inLanguage\":\"zh-TW\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/4-05_BN.jpg\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/4-05_BN.jpg\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/dial-thermometer-accuracy\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sj-gauge.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Accuracy Class and Limits of Error of Dial Thermometers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"name\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\",\"description\":\"Manufacturer of industrial pressure gauges, pressure sensors, and transmitters. SJ Gauge provides high accuracy, durable materials, and custom solutions for oil &amp; gas, chemical, and industrial applications.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sj-gauge.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-TW\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\",\"name\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"width\":348,\"height\":184,\"caption\":\"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\",\"name\":\"SJ Gauge\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"caption\":\"SJ Gauge\"},\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/zh-tw\\\/author\\\/sj-gauge\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u5ea6\u76e4\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\u7b49\u7d1a\u548c\u8aa4\u5dee\u7bc4\u570d - SJ Gauge | \u58d3\u529b\u8a08\u3001\u6eab\u5ea6\u8a08\u548c\u58d3\u529b\u50b3\u611f\u5668","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/","og_locale":"zh_TW","og_type":"article","og_title":"The Accuracy Class and Limits of Error of Dial Thermometers","og_description":"The accuracy of dial thermometers is crucial in industrial processes and decision-making. However, this important step is often overlooked in our daily use of temperature-measuring tools, with many assuming that temperature sensors are always accurate \u2014 a common misconception. Whether in energy supply, medical and food technology, chemical and pharmaceutical industries, or shipping and automotive, [&hellip;]","og_url":"https:\/\/www.sj-gauge.com\/zh-tw\/dial-thermometer-accuracy\/","og_site_name":"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors","article_published_time":"2022-08-13T05:52:35+00:00","article_modified_time":"2026-04-25T14:16:55+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg","type":"image\/jpeg"}],"author":"SJ Gauge","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005:":"SJ Gauge","\u9810\u4f30\u95b1\u8b80\u6642\u9593":"4 \u5206\u9418"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#article","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/"},"author":{"name":"SJ Gauge","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c"},"headline":"The Accuracy Class and Limits of Error of Dial Thermometers","datePublished":"2022-08-13T05:52:35+00:00","dateModified":"2026-04-25T14:16:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/"},"wordCount":723,"publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"image":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg","keywords":["Temperature"],"articleSection":["Knowledge"],"inLanguage":"zh-TW"},{"@type":"WebPage","@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/","url":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/","name":"\u5ea6\u76e4\u6eab\u5ea6\u8a08\u7684\u7cbe\u5ea6\u7b49\u7d1a\u548c\u8aa4\u5dee\u7bc4\u570d - SJ Gauge | \u58d3\u529b\u8a08\u3001\u6eab\u5ea6\u8a08\u548c\u58d3\u529b\u50b3\u611f\u5668","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#primaryimage"},"image":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg","datePublished":"2022-08-13T05:52:35+00:00","dateModified":"2026-04-25T14:16:55+00:00","breadcrumb":{"@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#breadcrumb"},"inLanguage":"zh-TW","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/"]}]},{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#primaryimage","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/12\/4-05_BN.jpg","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.sj-gauge.com\/dial-thermometer-accuracy\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sj-gauge.com\/"},{"@type":"ListItem","position":2,"name":"The Accuracy Class and Limits of Error of Dial Thermometers"}]},{"@type":"WebSite","@id":"https:\/\/www.sj-gauge.com\/#website","url":"https:\/\/www.sj-gauge.com\/","name":"SJ Gauge | \u58d3\u529b\u8a08\u3001\u6eab\u5ea6\u8a08\u53ca\u58d3\u529b\u50b3\u611f\u5668","description":"\u5de5\u696d\u58d3\u529b\u9336\u3001\u58d3\u529b\u611f\u6e2c\u5668\u548c\u50b3\u9001\u5668\u88fd\u9020\u5546\u3002SJ Gauge \u70ba\u6cb9\u6c23\u3001\u5316\u5b78\u548c\u5de5\u696d\u61c9\u7528\u63d0\u4f9b\u9ad8\u6e96\u78ba\u5ea6\u3001\u8010\u7528\u6750\u6599\u548c\u5ba2\u88fd\u5316\u89e3\u6c7a\u65b9\u6848\u3002.","publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sj-gauge.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-TW"},{"@type":"Organization","@id":"https:\/\/www.sj-gauge.com\/#organization","name":"SJ Gauge | \u58d3\u529b\u8a08\u3001\u6eab\u5ea6\u8a08\u53ca\u58d3\u529b\u50b3\u611f\u5668","url":"https:\/\/www.sj-gauge.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","width":348,"height":184,"caption":"SJ Gauge | Pressure Gauges, Thermometers &amp; Pressure Sensors"},"image":{"@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c","name":"SJ Gauge","image":{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","caption":"SJ Gauge"},"url":"https:\/\/www.sj-gauge.com\/zh-tw\/author\/sj-gauge\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/2683","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/comments?post=2683"}],"version-history":[{"count":2,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/2683\/revisions"}],"predecessor-version":[{"id":2790,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/2683\/revisions\/2790"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/media\/2684"}],"wp:attachment":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/media?parent=2683"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/categories?post=2683"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/tags?post=2683"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}