{"id":4223,"date":"2024-04-13T23:36:00","date_gmt":"2024-04-13T15:36:00","guid":{"rendered":"https:\/\/www.sj-gauge.com\/?p=4223"},"modified":"2026-04-20T20:25:55","modified_gmt":"2026-04-20T12:25:55","slug":"pressure-gauge-vacuum-issues","status":"publish","type":"post","link":"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/","title":{"rendered":"\u70ba\u4ec0\u9ebc\u58d3\u529b\u9336\u62bd\u4e0d\u5230760mmHg\uff1f\u58d3\u529b\u8a08\u600e\u9ebc\u62bd\u771f\u7a7a\uff1f"},"content":{"rendered":"<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u771f\u7a7a\u8a08\u7528\u4f86\u6e2c\u91cf\u76ee\u524d\u7684\u771f\u7a7a\u5ea6\uff0c\u4e00\u822c\u4ee5\u5927\u6c23\u58d3\u529b\u505a\u70ba\u96f6\u9ede\uff0c\u56e0\u6b64\u771f\u7a7a\u8a08\u7684\u6700\u5927\u503c\u70ba 760mmHg\uff08\u6216 76cmHg\uff09\uff0c\u8868\u793a\u5b8c\u5168\u771f\u7a7a\u3002\u4f46\u70ba\u4ec0\u9ebc\u5e38\u5e38\u5728\u4f7f\u7528\u4e0a\uff0c\u771f\u7a7a\u8a08\u90fd\u7121\u6cd5\u5230\u9054\u6700\u5927\u503c\u5462? SJ \u7098\u73c8\u5100\u9336\u5224\u65b7\u6709\u4ee5\u4e0b\u7684\u5e7e\u7a2e\u53ef\u80fd<\/p>\n<\/blockquote>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u76ee\u9304<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u986f\u793a\/\u96b1\u85cf\u5167\u5bb9\u76ee\u9304\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u5207\u63db<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #7b1e1c;color:#7b1e1c\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #7b1e1c;color:#7b1e1c\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#1-the-vacuum-gauge-itself-is-faulty\" >1. \u771f\u7a7a\u8a08\u6545\u969c<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#2-the-piping-or-fittings-are-not-completely-sealed\" >2. \u7ba1\u8def\u7ba1\u4ef6\u6c92\u6709\u5b8c\u5168\u5bc6\u5c01<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#3-the-vacuum-pump-or-vacuum-motor-has-performance-limitations\" >3. \u771f\u7a7a\u99ac\u9054\u7684\u554f\u984c<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#4-the-pressure-inside-the-gauge-case-is-not-balanced-with-ambient-pressure\" >4. \u771f\u7a7a\u8a08\u6bbc\u5167\u58d3\u529b\u8207\u5916\u754c\u58d3\u529b\u4e0d\u5e73\u8861<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#5-the-effect-of-atmospheric-pressure-and-altitude\" >5. \u5927\u6c23\u58d3\u529b(\u6d77\u62d4\u9ad8\u5ea6)\u7684\u5f71\u97ff<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/#conclusion\" >\u7e3d\u7d50<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-36f2f2ff83901a7e1dd62cd567f955f8\" id=\"h-1-the-vacuum-gauge-itself-is-faulty\"><span class=\"ez-toc-section\" id=\"1-the-vacuum-gauge-itself-is-faulty\"><\/span>1. \u771f\u7a7a\u8a08\u6545\u969c<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u56e0\u771f\u7a7a\u8a08\u672c\u8eab\u4e0d\u8010\u78b0\u649e\uff0c\u53ea\u8981\u4e00\u6709\u78b0\u649e\uff0c\u5c31\u6703\u7522\u751f\u4e0d\u6b78\u96f6\uff0c\u6e2c\u91cf\u4e0d\u6e96\u78ba\u7b49\u554f\u984c\u3002\u56e0\u6b64\u5728\u51fa\u8ca8\u524d\u5c31\u9700\u6aa2\u9a57\u904e\u5168\u90e8\u7684\u771f\u7a7a\u8a08\uff0c\u78ba\u8a8d\u8ca8\u54c1\u662f\u53ef\u7528\u7684\uff0c\u4e26\u4e14\u9700\u59a5\u5584\u4fdd\u8b77\u6bcf\u500b\u771f\u7a7a\u8a08\uff0c\u4ee5\u907f\u514d\u5728\u904b\u9001\u904e\u7a0b\u4e2d\uff0c\u767c\u751f\u56e0\u78b0\u649e\u800c\u7522\u751f\u7684\u640d\u58de\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-72f66da7a7e89bf3d305b60db3740c47\" id=\"h-2-the-piping-or-fittings-are-not-completely-sealed\"><span class=\"ez-toc-section\" id=\"2-the-piping-or-fittings-are-not-completely-sealed\"><\/span>2. \u7ba1\u8def\u7ba1\u4ef6\u6c92\u6709\u5b8c\u5168\u5bc6\u5c01<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u56e0\u771f\u7a7a\u5ea6\u7684\u6e2c\u91cf\uff0c\u53d7\u5230\u5927\u6c23\u58d3\u529b\u5f88\u5927\u7684\u5f71\u97ff\uff0c\u53ea\u8981\u6709\u4efb\u4f55\u53ef\u4ee5\u8b93\u7a7a\u6c23\u9032\u5165\u7ba1\u8def\u5143\u4ef6\u7684\u7e2b\u9699\uff0c\u5c31\u6c92\u6709\u8fa6\u6cd5\u9054\u5230\u6700\u5927\u771f\u7a7a\u5ea6\u3002\u6240\u4ee5\u8981\u91cf\u6e2c\u5230\u6700\u5927\u771f\u7a7a\u5ea6\uff0c\u9808\u78ba\u4fdd\u5f9e\u771f\u7a7a\u99ac\u9054\u5230\u771f\u7a7a\u8a08\u7684\u904e\u7a0b\u4e2d\uff0c\u4efb\u4f55\u9023\u63a5\u90fd\u662f\u9023\u63a5\u5bc6\u5c01\u7684\uff0c\u624d\u4e0d\u6703\u53d7\u5230\u5927\u6c23\u58d3\u529b\u5f71\u97ff\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-8ae3487328c853785c3237935cbb4304\" id=\"h-3-the-vacuum-pump-or-vacuum-motor-has-performance-limitations\"><span class=\"ez-toc-section\" id=\"3-the-vacuum-pump-or-vacuum-motor-has-performance-limitations\"><\/span>3. \u771f\u7a7a\u99ac\u9054\u7684\u554f\u984c<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u6709\u4e9b\u771f\u7a7a\u99ac\u9054\u7684\u8a2d\u8a08\uff0c\u50c5\u80fd\u9054\u5230\u63a5\u8fd1\u5b8c\u5168\u771f\u7a7a\u800c\u4e0d\u6703\u5230\u5b8c\u5168\u771f\u7a7a\u3002\u6b64\u5916\uff0c\u7576\u771f\u7a7a\u6cf5\u904e\u65bc\u8001\u820a\uff0c\u4e5f\u7121\u6cd5\u5b8c\u5168\u767c\u63ee\u5176\u6027\u80fd\uff0c\u6240\u4ee5\u4e5f\u4e0d\u4e00\u5b9a\u6703\u9054\u5230\u5b8c\u5168\u771f\u7a7a\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-67b4bc342eac86e3222a57f36076ca41\" id=\"h-4-the-pressure-inside-the-gauge-case-is-not-balanced-with-ambient-pressure\"><span class=\"ez-toc-section\" id=\"4-the-pressure-inside-the-gauge-case-is-not-balanced-with-ambient-pressure\"><\/span>4. \u771f\u7a7a\u8a08\u6bbc\u5167\u58d3\u529b\u8207\u5916\u754c\u58d3\u529b\u4e0d\u5e73\u8861<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u6b64\u7a2e\u73fe\u8c61\u4e0d\u4e00\u5b9a\u6703\u4f7f\u771f\u7a7a\u8a08\u986f\u793a\u4e0d\u5230 760mmHg\uff0c\u4f46\u6703\u8b93\u771f\u7a7a\u8a08\u7684\u8b80\u8cea\u6709\u8aa4\u5dee\u3002\u82e5\u771f\u7a7a\u8a08\u6bbc\u5167\u662f\u5bc6\u5c01\u72c0\u614b\uff0c\u4e26\u6c92\u6709\u8207\u5916\u90e8\u7684\u74b0\u5883\u505a\u6c23\u9ad4\u4ea4\u63db\uff0c\u5247\u8207\u7ba1\u8def\u7cfb\u7d71\u7684\u58d3\u529b\u96f6\u9ede\u4e0d\u540c\uff0c\u6e2c\u91cf\u5230\u7684\u8b80\u8cea\u5c31\u8207\u7ba1\u8def\u7cfb\u7d71\u7684\u6642\u969b\u771f\u7a7a\u5ea6\u4e0d\u540c\u3002\u6216\u6709\u6642\u771f\u7a7a\u8a08\u6bbc\u5167\u6eab\u5ea6\u8f03\u9ad8\uff0c\u53c8\u6c92\u6709\u8207\u5916\u754c\u7684\u7a7a\u6c23\u6d41\u901a\uff0c\u6703\u9020\u6210\u6bbc\u5167\u58d3\u529b\u7565\u9ad8\u65bc\u5916\u754c\u58d3\u529b\uff0c\u4f7f\u771f\u7a7a\u8a08\u4e0d\u6b78\u96f6\uff0c\u6e2c\u91cf\u5230\u7684\u8b80\u8cea\u4e5f\u6703\u4e0d\u6e96\u78ba\u3002\u4ee5\u4e0a\u9019\u5169\u7a2e\u60c5\u6cc1\u7684\u89e3\u6c7a\u65b9\u6cd5\u76f8\u540c\uff0c\u53ea\u8981\u6253\u958b\u6cb9\u585e\u84cb\uff0c\u5c31\u80fd\u4f7f\u6bbc\u5167\u58d3\u529b\u8207\u5916\u63a5\u58d3\u529b\u5e73\u8861\uff0c\u4fbf\u80fd\u5f97\u6e96\u78ba\u7684\u58d3\u529b\u4e86\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-88c9970c20c2b36711b9e6bd3b49b200\" id=\"h-5-the-effect-of-atmospheric-pressure-and-altitude\"><span class=\"ez-toc-section\" id=\"5-the-effect-of-atmospheric-pressure-and-altitude\"><\/span>5. \u5927\u6c23\u58d3\u529b(\u6d77\u62d4\u9ad8\u5ea6)\u7684\u5f71\u97ff<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u6211\u5011\u5e38\u8aaa\u7684\u6a19\u6e96\u5927\u6c23\u58d3\u529b\u662f\u6307\u5728\u6d77\u5e73\u9762\u4e0a\u6e2c\u5f97\u7684\u7d55\u5c0d\u58d3\u529b\uff0c\u70ba 760mmHg\uff0c\u56e0\u6b64\u771f\u7a7a\u8a08\u4e0a\u6240\u6a19\u793a\u7684 -760mmHg \u6307\u7684\u662f\u5728\u6d77\u5e73\u9762\u7684\u5b8c\u5168\u771f\u7a7a\u3002\u4f46\u4e00\u822c\u771f\u7a7a\u8a08\u7684\u96f6\u9ede\u70ba\u5916\u754c\u5927\u6c23\u58d3\u529b\uff0c\u6703\u53d7\u6e2c\u91cf\u9ede\u7684\u6d77\u62d4\u9ad8\u5ea6\u5f71\u97ff\u3002\u4f8b\u5982\u7576\u6d77\u62d4\u4e0a\u5347\u5230240\u516c\u5c3a\u6642\uff0c\u5916\u754c\u7684\u5927\u6c23\u7684\u7d55\u5c0d\u58d3\u529b\u50c5\u6709 740mmHg\uff0c\u6240\u4ee5\u5728\u6b64\u6d77\u62d4\u4e0b\uff0c\u82e5\u6c92\u6709\u5176\u4ed6\u63a7\u5236\u689d\u4ef6\uff0c\u5373\u4f7f\u7ba1\u8def\u5167\u90e8\u5df2\u7d93\u5b8c\u5168\u771f\u7a7a\uff0c\u771f\u7a7a\u8a08\u4e0a\u4e5f\u53ea\u6703\u986f\u793a -740mmHg\u3002\u771f\u7a7a\u8a08\u7684\u96f6\u9ede\u5176\u5be6\u8ddf\u4e00\u822c\u58d3\u529b\u8a08\u7684\u96f6\u9ede\u4e00\u6a23\uff0c\u6703\u96a8\u6d77\u62d4\u9ad8\u5ea6\u800c\u6539\u8b8a\uff0c\u53ea\u662f\u4e00\u822c\u6211\u5011\u5e38\u7528\u7684\u58d3\u529b\u8a08\uff0c\u6e2c\u91cf\u7bc4\u570d\u8f03\u5927\uff0c\u4e0d\u592a\u6703\u53d7\u5927\u6c23\u58d3\u529b\u800c\u5f71\u97ff\u5176\u6e2c\u91cf\u503c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-palette-color-2-color has-text-color has-link-color wp-elements-6421794a017bba9c18be30b5cea78077\" id=\"h-conclusion\"><span class=\"ez-toc-section\" id=\"conclusion\"><\/span>\u7e3d\u7d50<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u7d9c\u4e0a\u6240\u8ff0\uff0c\u771f\u7a7a\u8a08\u662f\u5c6c\u65bc\u8f03\u654f\u611f\u7684\u6e2c\u91cf\u5100\u9336\uff0c\u5f88\u5bb9\u6613\u53d7\u5230\u5916\u754c\u5404\u7a2e\u56e0\u7d20\u7684\u5f71\u97ff\u3002\u6240\u4ee5\u7576\u4e0b\u6b21\u767c\u73fe\u771f\u7a7a\u8a08\u53c8\u7121\u6cd5\u6e2c\u91cf\u5230 -760mmHg \u6642\uff0c\u53ef\u4ee5\u770b\u770b\u6709\u6c92\u6709\u4e0a\u8ff0\u60c5\u6cc1\u767c\u751f\uff0c\u907f\u514d\u4e00\u76f4\u66f4\u63db\u771f\u7a7a\u8a08\uff0c\u537b\u5f92\u52de\u7121\u529f\u7684\u60c5\u4e8b\u767c\u751f\u3002<br><\/p>","protected":false},"excerpt":{"rendered":"<p>A vacuum gauge is used to measure the vacuum level inside a system. In general, atmospheric pressure is taken as the reference zero point, so under standard atmospheric pressure at sea level, the maximum reading of a vacuum gauge is about -760 mmHg (or -76 cmHg), which represents a near-perfect vacuum condition. However, in actual [&hellip;]<\/p>","protected":false},"author":2,"featured_media":4309,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[61],"tags":[71],"class_list":["post-4223","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge","tag-pressure"],"blocksy_meta":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.7 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Why Can\u2019t a Vacuum Gauge Reach -760 mmHg? Causes &amp; Solutions\uff5cSJ Gauge<\/title>\n<meta name=\"description\" content=\"A vacuum gauge should reach -760 mmHg under ideal conditions, but in real applications, it often falls short. Learn the common causes such as leaks, faulty gauges, and system limitations, and how to improve vacuum performance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/\" \/>\n<meta property=\"og:locale\" content=\"zh_TW\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?\" \/>\n<meta property=\"og:description\" content=\"A vacuum gauge should reach -760 mmHg under ideal conditions, but in real applications, it often falls short. Learn the common causes such as leaks, faulty gauges, and system limitations, and how to improve vacuum performance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/\" \/>\n<meta property=\"og:site_name\" content=\"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-13T15:36:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-20T12:25:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"SJ Gauge\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005:\" \/>\n\t<meta name=\"twitter:data1\" content=\"SJ Gauge\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9810\u4f30\u95b1\u8b80\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\u9418\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/\"},\"author\":{\"name\":\"SJ Gauge\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\"},\"headline\":\"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?\",\"datePublished\":\"2024-04-13T15:36:00+00:00\",\"dateModified\":\"2026-04-20T12:25:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/\"},\"wordCount\":798,\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg\",\"keywords\":[\"Pressure\"],\"articleSection\":[\"Knowledge\"],\"inLanguage\":\"zh-TW\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/\",\"name\":\"Why Can\u2019t a Vacuum Gauge Reach -760 mmHg? Causes & Solutions\uff5cSJ Gauge\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg\",\"datePublished\":\"2024-04-13T15:36:00+00:00\",\"dateModified\":\"2026-04-20T12:25:55+00:00\",\"description\":\"A vacuum gauge should reach -760 mmHg under ideal conditions, but in real applications, it often falls short. Learn the common causes such as leaks, faulty gauges, and system limitations, and how to improve vacuum performance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#breadcrumb\"},\"inLanguage\":\"zh-TW\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/pressure-gauge-vacuum-issues\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sj-gauge.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#website\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"name\":\"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge\",\"description\":\"Manufacturer of industrial pressure gauges, pressure sensors, and transmitters. SJ Gauge provides high accuracy, durable materials, and custom solutions for oil &amp; gas, chemical, and industrial applications.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sj-gauge.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-TW\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#organization\",\"name\":\"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/www.sj-gauge.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.webp\",\"width\":348,\"height\":184,\"caption\":\"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.sj-gauge.com\\\/#\\\/schema\\\/person\\\/cbc9e642e49a53b18b3eb832486bd52c\",\"name\":\"SJ Gauge\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-TW\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g\",\"caption\":\"SJ Gauge\"},\"url\":\"https:\\\/\\\/www.sj-gauge.com\\\/zh-tw\\\/author\\\/sj-gauge\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u70ba\u4ec0\u9ebc\u771f\u7a7a\u8a08\u7121\u6cd5\u9054\u5230 -760 mmHg\uff1f\u539f\u56e0\u8207\u89e3\u6c7a\u65b9\u6cd5\uff5cSJ Gauge","description":"\u771f\u7a7a\u8a08\u7406\u8ad6\u4e0a\u53ef\u9054 -760 mmHg\uff0c\u4f46\u5be6\u969b\u61c9\u7528\u4e2d\u5e38\u7121\u6cd5\u9054\u5230\u3002\u672c\u6587\u89e3\u6790\u5e38\u898b\u539f\u56e0\uff0c\u5305\u62ec\u6f0f\u6c23\u3001\u8a2d\u5099\u554f\u984c\u8207\u5b89\u88dd\u4e0d\u826f\uff0c\u5e6b\u52a9\u60a8\u63d0\u5347\u771f\u7a7a\u7cfb\u7d71\u6548\u80fd\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/","og_locale":"zh_TW","og_type":"article","og_title":"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?","og_description":"A vacuum gauge should reach -760 mmHg under ideal conditions, but in real applications, it often falls short. Learn the common causes such as leaks, faulty gauges, and system limitations, and how to improve vacuum performance.","og_url":"https:\/\/www.sj-gauge.com\/zh-tw\/pressure-gauge-vacuum-issues\/","og_site_name":"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge","article_published_time":"2024-04-13T15:36:00+00:00","article_modified_time":"2026-04-20T12:25:55+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg","type":"image\/jpeg"}],"author":"SJ Gauge","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005:":"SJ Gauge","\u9810\u4f30\u95b1\u8b80\u6642\u9593":"4 \u5206\u9418"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#article","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/"},"author":{"name":"SJ Gauge","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c"},"headline":"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?","datePublished":"2024-04-13T15:36:00+00:00","dateModified":"2026-04-20T12:25:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/"},"wordCount":798,"publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"image":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg","keywords":["Pressure"],"articleSection":["Knowledge"],"inLanguage":"zh-TW"},{"@type":"WebPage","@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/","url":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/","name":"\u70ba\u4ec0\u9ebc\u771f\u7a7a\u8a08\u7121\u6cd5\u9054\u5230 -760 mmHg\uff1f\u539f\u56e0\u8207\u89e3\u6c7a\u65b9\u6cd5\uff5cSJ Gauge","isPartOf":{"@id":"https:\/\/www.sj-gauge.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#primaryimage"},"image":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg","datePublished":"2024-04-13T15:36:00+00:00","dateModified":"2026-04-20T12:25:55+00:00","description":"\u771f\u7a7a\u8a08\u7406\u8ad6\u4e0a\u53ef\u9054 -760 mmHg\uff0c\u4f46\u5be6\u969b\u61c9\u7528\u4e2d\u5e38\u7121\u6cd5\u9054\u5230\u3002\u672c\u6587\u89e3\u6790\u5e38\u898b\u539f\u56e0\uff0c\u5305\u62ec\u6f0f\u6c23\u3001\u8a2d\u5099\u554f\u984c\u8207\u5b89\u88dd\u4e0d\u826f\uff0c\u5e6b\u52a9\u60a8\u63d0\u5347\u771f\u7a7a\u7cfb\u7d71\u6548\u80fd\u3002","breadcrumb":{"@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#breadcrumb"},"inLanguage":"zh-TW","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/"]}]},{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#primaryimage","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2026\/04\/SJ-Gauge-Pressure-Gauge-Measure-VacuumBN.jpg","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/www.sj-gauge.com\/pressure-gauge-vacuum-issues\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sj-gauge.com\/"},{"@type":"ListItem","position":2,"name":"Why Can`t a Vacuum Gauge Reach -760 mmHg? How Does a Pressure Gauge Measure Vacuum?"}]},{"@type":"WebSite","@id":"https:\/\/www.sj-gauge.com\/#website","url":"https:\/\/www.sj-gauge.com\/","name":"\u60a8\u7684\u58d3\u529b\u6eab\u5ea6\u8207\u667a\u6167\u578b\u50b3\u9001\u5668\u5c08\u5bb6 - SJ Gauge","description":"\u5de5\u696d\u58d3\u529b\u9336\u3001\u58d3\u529b\u611f\u6e2c\u5668\u548c\u50b3\u9001\u5668\u88fd\u9020\u5546\u3002SJ Gauge \u70ba\u6cb9\u6c23\u3001\u5316\u5b78\u548c\u5de5\u696d\u61c9\u7528\u63d0\u4f9b\u9ad8\u6e96\u78ba\u5ea6\u3001\u8010\u7528\u6750\u6599\u548c\u5ba2\u88fd\u5316\u89e3\u6c7a\u65b9\u6848\u3002.","publisher":{"@id":"https:\/\/www.sj-gauge.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sj-gauge.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-TW"},{"@type":"Organization","@id":"https:\/\/www.sj-gauge.com\/#organization","name":"\u60a8\u7684\u58d3\u529b\u6eab\u5ea6\u8207\u667a\u6167\u578b\u50b3\u9001\u5668\u5c08\u5bb6 - SJ Gauge","url":"https:\/\/www.sj-gauge.com\/","logo":{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","contentUrl":"https:\/\/www.sj-gauge.com\/wp-content\/uploads\/2025\/09\/logo.webp","width":348,"height":184,"caption":"Your Expert in Pressure Temp and Smart Transmitters - SJ Gauge"},"image":{"@id":"https:\/\/www.sj-gauge.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.sj-gauge.com\/#\/schema\/person\/cbc9e642e49a53b18b3eb832486bd52c","name":"SJ Gauge","image":{"@type":"ImageObject","inLanguage":"zh-TW","@id":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4e493d7a75385cd872b842b9ce5fd061df6540ad1ac291892ca82dcf5d1ea59b?s=96&d=mm&r=g","caption":"SJ Gauge"},"url":"https:\/\/www.sj-gauge.com\/zh-tw\/author\/sj-gauge\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/4223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/comments?post=4223"}],"version-history":[{"count":1,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/4223\/revisions"}],"predecessor-version":[{"id":4224,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/posts\/4223\/revisions\/4224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/media\/4309"}],"wp:attachment":[{"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/media?parent=4223"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/categories?post=4223"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sj-gauge.com\/zh-tw\/wp-json\/wp\/v2\/tags?post=4223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}